Re: A-156 Dual Quantizer Transpose issue

2015-03-20 by karelvanbezooijen@yahoo.com

This is what I did: http://www.pulsepsycle.nl/wp-content/uploads/doepfer_a156.jpg



Now when I apply 1 volt to the upper Quantizer CV In it reads 1.006 volt at the CV Out instead of 0.924 volt so that's all right.
But after adding another 2 volt at Transpose CV In reads 2.918 volt so that's not right. Without the 330K resistor it then reads 2.836 volt.

I didn't solder anything yet. Just used clamps and cables to test.

Best regards,

Karel.