AW: [Doepfer_a100] A190-4 Reset Issue

2016-09-19 by yahoo@doepfer.de

> Hi  - I'm using the A190-4 as my midi interface, with master
> clock provided by an ERM Midiclock unit.
>
>
> When I hit start, the clock starts but the Reset light activates
> on the A190-4.  When I reset from the ERM nothing happens. When I
> stop the ERM the clock stops (obviously) and the reset light goes off.
>
>
> Now, the ERM sends the clock pulse and the only other controls on
> the unit are play/pause and resync/reset buttons.  Hitting it
> during playback works to resynchronise all devices by resetting
> the song position pointer at the start of the next bar.
> Effectively this means that any devices which have slipped out of
> sync are immediately and seamlessly restarted without
> interrupting playback.
>
>
> Any suggestions as to what's happening ?

The Reset output of the A-190-4 is controlled by Midi Start/Stop messages.
These messages have to be transmitted to the A-190-4. Otherwise the Reset
will not react. Details in the A-190-4 user's manual.

Best wishes
Dieter Doepfer