Hi, I'm glad to report that I'm up and running again. Pretty sure that the problem was caused by some ribbon connectors that had come partially adrift - all it needed was a new fuse. Thanks to all who've educated me, yet again. Best wishes. Tim Burgess -----Original Message----- From: Doepfer_a100@yahoogroups.com [mailto:Doepfer_a100@yahoogroups.com] Sent: 16 February 2018 12:24 To: Doepfer_a100@yahoogroups.com Subject: AW: [Doepfer_a100] Troubleshooting lack of power on LC9 > Hi, > > This is the point I'd like clarification on myself. A U.K. dealer has > told me that there's 1200mA available spread across both the positive > and negative supplies, so I'm confused. > > Best wishes. > > Tim Burgess This information was wrong. The A-100PSU2 outputs 1200mA for +12V AND 1200mA for -12V. If you have problems with the supply or system please refer to our FAQ page: www.doepfer.com > English > FAQ > A-100 > My A-100 system does no longer work Here you find some hints to find out what's wrong if the fuse does blow. Best wishes Dieter Doepfer ------------------------------------ ------------------------------------ ------------------------------------ Yahoo Groups Links