Yahoo Groups archive

Doepfer

Index last updated: 2026-04-29 00:15 UTC

Message

Re: [Doepfer_a100] Re: Blown Fuse!

2003-04-18 by Bakis Sirros

hi tim,
it's better for dan to contact his doepfer dealers or
roland mayer,as dieter is away from the office until
22 of april.
bakis.


--- Tim Stinchcombe
<timothy@tstinchcombe.freeserve.co.uk> wrote:
> Hi Dan,
> 
> We've had this discussion in the past, and there
> seems to be a 
> difference in opinion as to what type of fuse to
> use. In mine (I'm UK 
> based) the fuses are marked 'T100mA', which makes
> them 'time lag' 
> (or 'slo-blo') fuses. The point of them being
> time-lag is to ensure 
> that they don't blow at the moment of turn on, when
> an inevitable 
> surge in current occurs. If the replacements you
> used were not 'T' 
> types, then this may be why they blew immediately.
> On the other hand, 
> you may of course actually have a problem somewhere
> with something 
> drawing too much current! However, other list
> members have suggested 
> using fast blow types as an added precaution.
> Probably best to 
> contact your local distributor; but come to think
> about it, perhaps 
> if Dieter is listening in, he can put us straight
> once and for all?!
> 
> Tim
> 
> 
> --- In Doepfer_a100@yahoogroups.com, "danielthouin" 
> <danielthouin@h...> wrote:
> > Hi,
> > I am a new user from Montreal, Canada.
> > The fuse that came with my A-100 blowed and it was
> a 0.1 Ma.
> > I replaced it with another 0,1 and it  blowed
> again and again.
> > Now I have put a 0.5 and it seems fine but I don't
> want to blow 
> > somethingelse.
> > Anybody with a clue
> > Thanks
> > Dan
> 
> 


=====
synthfreak(parallel worlds)
athens-greece
[Doepfer_a100] group owner

__________________________________________________
Do you Yahoo!?
The New Yahoo! Search - Faster. Easier. Bingo
http://search.yahoo.com

Attachments