> Best to contact the distributer, who has probably answered this > question many times. Here in the U.S. Enport told me that all of the > frames shipped here from Doepfer contain fuses sized for the 220V P/S, > even though the frames have a 110V P/S, which is why the fuses always > blow. After what I've just read on the web, I'll definitely second that! When I first read the above I have to admit to being a little sceptical - several of the books I have point out that fuses and their ratings are a very misunderstood subject, but then they don't really give the whole story. I thought it was a power thing, but in fact it is a current thing - hence on the basis the psu takes the same power whether running off 240V or 110V, in the US/Canada, half the voltage implies *double* the current, so what Joe says above sounds very feasible. After searching the web (it's called 'fuseology', what a yeuchy term!) I came across this: http://www.littelfuse.com/PDFs/EDG_Cat/Fuseology.pdf Take a gander if you want to be convinced by the complexity of it! I'm thus a little surprised that Doepfer ship units to North America with the same fuse rating as Europe when it looks like it could be a little marginal - it would be nice to hear Dieter's take on it. In any case, it sounds like Dan has his system running OK, at least in the short term. Tim
Message
Re: Blown Fuse!
2003-04-18 by Tim Stinchcombe