Re: [Doepfer_a100] Re: Blown fuse again!

2003-06-02 by Bakis Sirros

hi roel,
so,it seems that the problem is in the case's bus
board!as all the new modules have worked in your
other(older) doepfer case,they seem to be ok!
as far as i know from dieter,yes, a wrong connection
to the bus board can lead to a blown fuse!
but,also, check that your new "defective" doepfer case
is set for 230 volts(europe)operation and NOT for 115
volts!
bakis.


--- Roel Steverink <r.steverink@wanadoo.nl> wrote:
> From:   "Tim Stinchcombe" <timothy@t...>
> Date:  Mon Jun 2, 2003  8:21 pm
> Subject:  Re: Blown fuse again!
> 
> Hi Tim,
> 
> With both cases I had the new modules connected to
> the bus.
> The fuse of the first case, must have been blown,
> due to an overload situation (I had to many gear on
> one socket).
> By that time I had brought back the first case
> to Music house in Utrecht (netherlands) and swopped
> that for a new one.
> The same happened with the second case, then I
> relieved the overload and I had a save situation
> again.
> This afternoon, after work, I bought two T100ma
> fuses.
> Now, with the overload being rid off, I shouldn't
> experience any problems anymore, right!
> Both fuses blew immediately, which led me to the
> conclusion, that something else was wrong!
> 
> I checked, yes I had all the modules connected with
> the red stripe on the ribbon at the bottom.
> Yes, in the second case the second connector on the
> bus board has the first two pins slightly sticking
> outside. I remember the trouble I had to stick it
> in!
> But can one wrong connection on the bus board led
> to an immediately blown fuse?
> Yes, I tested the modules in an other working case,
> all were fine.
> 
> Believe I already have set the wheels in motion.
> Phoned with Utrecht. Last friday they should have
> checked the case and hopefully they can tell what's
> wrong with it.
> I send Bakis a mail and he immediately send one
> to Doepfer and simultaneously I had done the same!
> And this evening I got an answer from Dieter
> himself,
> which I have anwsered before I made this posting.
> I explained the whole situation and I know I'm
> anxiously
> waiting his answers.
> 
> Thanks for your interest.
> 
> Roel.
> 
> 
> 
> >Hi Roel,
> 
> >Is this with the case empty, i.e. no modules in it?
> If so, since it's
> >a new case, time to contact your local distributor!
> If you _have_ put
> >some modules in: are they all connected the right
> way round, i.e. the
> >red stripe on the ribbon at the bottom?; have any
> of the connectors
> >been forced on one pin too high or low?; are there
> any bent/damaged
> >pins on unused connectors shorting out?; are the
> modules known to
> >work in another case?
> 
> > Now, I know there's something
> > else not right!
> > This the second case this happends
> > with!
> 
> >What was the problem with the first one?
> 
> >Many, many possibilities, but unless it is a
> clearly obvious physical
> >problem (like the above), my advice: call your
> distributor!
> 
> Tim
> 
> > Today I bought 2 fuses of T100ma.
> > As soon as I switched the case on,
> > the fuse blew!!!
> > To make sure it was not a bad fuse,
> > I tried the spare one and...
> > it acted the same way!!!
> > I tell you also what happened to
> > the 250ma fuse I tried.
> > This kept working, but only the middle
> > control leds of the bus in the case,
> > was lighted. (I know 2 of them
> > should light when everything's ok�.
> 
> 


=====
synthfreak(parallel worlds)
athens-greece
[Doepfer_a100] group owner

__________________________________
Do you Yahoo!?
Yahoo! Calendar - Free online calendar with sync to Outlook(TM).
http://calendar.yahoo.com

Attachments

Move to quarantaine

This moves the raw source file on disk only. The archive index is not changed automatically, so you still need to run a manual refresh afterward.