--- Dieter Doepfer <hardware@doepfer.de> wrote: > From: "Dieter Doepfer" <hardware@doepfer.de> > To: "Bakis Sirros" <synth_freak_2000@yahoo.com> > Subject: AW: [Doepfer_a100] Re: about the a143-1 > again. > Date: Wed, 28 Jan 2004 18:54:57 +0100 > > > maybe i'm wrong on this, but when we have a > comparator > > with adjustable threshold included, we can also > have > > a trigger when the decay-phase begins, which will > be the > > same as an "end of attack phase" trigger. some > additional > > jacks would only be good if you want to generate > two > > triggers at different levels. > > Right. But the end of attack is nearly for free as > it is available in any > case (output of the flip-flop of the AD circuit). > Only the socket and the > wiring time has to be payed. So you would have 2 > different trig outs: end of > attack and beginning/middle/end of decay with > adjustable level. You may > trigger one succeeding AD with "end of attack" and > another with > "beginning/middle/end of decay". Just an idea. I > never tried it the > prototype is not yet available. > > Best wishes > Dieter Doepfer > > ===== Bakis Siros Parallel Worlds / Polariton Athens-Greece [Doepfer_a100] group owner http://www.rubber.gr http://www.ward12.com __________________________________ Do you Yahoo!? Yahoo! SiteBuilder - Free web site building tool. Try it! http://webhosting.yahoo.com/ps/sb/
Message
Fwd: AW: [Doepfer_a100] Re: about the a143-1 again.(dieter's comments)
2004-01-28 by Bakis Sirros