--- In Doepfer_a100@yahoogroups.com, "ilanode" <techmeier@w...> wrote: > > Hi Stuadh > > As to using different power boards, I'm assuming that this > refers > > to separate distribution boards, and not different PSUs? I can > easily install another > > dist board for the "noisy" modules. > > Actually that should solve the problem: 1 PSU to power the distrib. > boards for "clean" modules and another 1 for the "dirty" ones. Just > crossing my mind what your cap querry earlier might refered to: on > the Oakley distr. board 2 separate ground rails are connected > through a 470nF cap but this is of no help with the Doepfer board > since here all 6 ground pins are already connected on the board's > pcb. Regards, Ingo coool, there is another ingo around here :-) best wishes ingo ;-)