Re: a180

2001-08-02 by hens@gmx.net

--- bunnyman wrote:

> I want to modify my mult to the dual 4 unit. I know you only need
> to cut a jumper, but before I go snipping wires, I was wondering if
> anyone else had done this?

My manual says I need to remove the soldering connection.
so that's what I did. You can remove the A180 by unscrewing it
using the two front screws. Since it's passive and doesn't connect
to the sysbus, you can easily remove it. Then no cutting or
damaging, just heat your soldering device and remove the bridge
between connectors 4 and 5. You can also connect them again if
so desired, so no damage done. Works like a charm. If you have
a multimeter with a connection/resistance test, it's easy to check
if you really removed the connection.