> I will have to check the Highspeed VCO in the voicecard of the old > Doepfer Sound Sampling System. This worked really perfect. This had an electronic switch that was triggered by the rising edge of the gate signal. This switch was used to increase the filter frequency of the PLL low pass for a few milliseconds immediately after each gate transistion. Consequently the PLL frequency follows very fast for a few milliseconds the input frequency. After that the low pass returns to its normal lower frequency (~ 10 Hz or so). This feature is not included in the A-196 but could be added with an external filter (the A-171 in this case as a DC coupled filter is required). Best wishes Dieter Doepfer
Message
AW: [Doepfer_a100] Re: A-196 - good tracking hispeed VCO patch wanted;)
2005-02-16 by Dieter Doepfer