Hi Tim, many thanks for the information. best regards, heinz --- In Doepfer_a100@yahoogroups.com, "Tim Stinchcombe" <timothy@t...> wrote: > > Hi Heinz, > > > i have a question regarding the A-185 module (bus access). what > > exactly must i do to get it into 'read only' mode? > > according to the manual it depends on a jumper, but the module > sports > > two jumpers and there are no detailed instructions as to how to > > proceed (i'm unfortunately completely unknowledgeable w.r.t. > electronics). > > i want to mount the module in a frame that already HAS one A-185 > > mounted in it (i want additional CV and gate outputs on that frame) > > and apparently this doesn't work when both are in read/write mode. > > The manual does seem a little confusing, but I think most of the > information is there. Each section of the 185 (one for 'CV', the > other for 'gate') consists of a 'buffer' (or 'refresh amplifier' in > the manual) connected between the 'in' and 'out'. The jumpers control > whether the internal bus bar is connected to the in or out. In the > factory setting (with the jumper in the position of the thick line on > the PCB), the system bus is connected to the output, as Fig 1 shows. > Hence feed CV and gate signals from the 'master' to the inputs: this > then goes to the bus bar to which the A-185 is connected, *and also* > to the output sockets, so another A-185 on another bus bar can > be 'daisy-chained', as Fig 2 shows. > > If you swap the jumpers to the other position (for 'read mode'), the > system bus is connected to the inputs of the buffers, and hence the > buffered signals are avaliable at the outputs, this is Fig 3 (and > note that the diagram is a little incomplete: the input now *is* the > system bus, and so the statement immediately above it isn't correct!). > > If you are solely using Doepfer modules, there should be no need for > the read mode, as the manual says, as if you think you need to read > what is on the bus, you should be able to take it from what put in > there (either an A-185 or A-190, as Fig 2 shows). However if you have > a different module writing signals to the bus, and that is why you > need to read it using an A-185, then Doepfer have taken the view that > you know what you are doing, hence the "won't go into any more detail > here" statement (which is probably not unreasonable in my view!). > > And I hope this doesn't make things more confusing! > > Tim
Message
Re: greetings and an A-185 question
2005-02-16 by pater lacrymarum
Attachments
- No local attachments were found for this message.