Yahoo Groups archive

Doepfer

Index last updated: 2026-04-29 00:15 UTC

Message

AW: [Doepfer_a100] Re: MCV24

2005-02-21 by Dieter Doepfer

I'm not an MCV24 specialist but Florian's suggestion should normally solve
your problem.
Contact Christian Assall (software@doepfer.de) if you still have problems.
He programmed the MCV24 and knows how to invert the gate function.

Best wishes
Dieter Doepfer

> -----Ursprüngliche Nachricht-----
> Von: Antonio Grazioli [mailto:antonio_grazioli@fastwebnet.it]
> Gesendet: Montag, 21. Februar 2005 16:02
> An: Doepfer_a100@yahoogroups.com
> Betreff: [Doepfer_a100] Re: MCV24
>
>
>
>
> nope..i alredy tried this...
> it always outputs a reversed or inverted gate, tried also this
> settings with a A-165 and then it's OK...
>
> ??? ANY IDEA ???
>
>
> --- In Doepfer_a100@yahoogroups.com, Florian Anwander
> <Florian.Anwander@c...> wrote:
> > Hi Antonio
> >
> > > I used the standard couple CV OUTPUT1-->TRIGGER OUT on OUTPUT13
> > > I set up:
> > > trigger Level ON =100%
> > > trigger level OFF=000%
> > Does the gate work correct if you reverse this setting, like:
> >
> >   trigger Level ON =000%
> >   trigger level OFF=100%
> >
> > ?
> >
> > Florian
>
>
>
>
>
>
>
> Yahoo! Groups Links
>
>
>
>
>
>
>