Yahoo Groups archive

Doepfer

Index last updated: 2026-04-29 00:15 UTC

Message

Re: Doepfer A151

2005-04-15 by trebcavxx

Thanks for the hints. I do, in fact have four 8 channel sequencers. I 
plugged various of the outputs to the reset socket on the A151. My 
sequencers also have a selector knob (not standard) where I can 
select the sequence length more quickly than patching a cable from an 
output to the reset on them (They are An.Sol.SQ8's), and the only way 
I could get the A151 to reset after 3 was to patch the cable from 
channel 4 to the A151 reset socket, and at the same time have the SQ8 
sequence length selector set to a length of 7. Now, if anyone can 
figure out just why that works, they are better than I.
Richard

--- In Doepfer_a100@yahoogroups.com, "unknown freak" 
<vogelscheiss@v...> wrote:
> I'll be interested to hear an answer to this one.  I can't think 
how this
> can be done without more modules -- you need something counting to 
24.  Of
> course the new A151 has a switch allowing you to use it as a 1:3.  
With the
> old A151, in this configuration it seems like something that 
requires
> another sequencer or sequential switch -- a trigger output on step 
8 of
> sequencer 1 clocks the second sequencer, which resets after 3 
steps, multing
> off the reset signal to the A151's reset input.  I don't know, 
maybe I'm
> full of sh_t on this.  Other takers?
> 
> --Chuck
> 
> -----Original Message-----
> From: Doepfer_a100@yahoogroups.com 
[mailto:Doepfer_a100@yahoogroups.com] On
> Behalf Of trebcavxx
> Sent: Friday, April 15, 2005 2:56 PM
> To: Doepfer_a100@yahoogroups.com
> Subject: [Doepfer_a100] Doepfer A151
> 
> 
> 
> I've got a question about the Doepher A151 Sequential switch. Using 
the 
> switch in the fashion of inputting 3 CV feeds in, and taking an 
output 
> from the I/O socket, I'd need to input a reset signal into the 
reset 
> socket to cancel the 4th switching on each pass. Does anyone know 
where 
> I'd get the pulse from to do this ?  
> I'm feeding in three CVs from three Analogue Sol sequencers into 
1,2 
> and 3, then taking the output from the I/O socket to my quantiser, 
and 
> then on to the CV input of a VCO. The switching pulse for the A151 
is 
> coming from the 1:8 output of my master clock. The 1:1 output goes 
to 
> the three sequencer's CLOCK inputs, (and also to the TRIG of an 
> envelope generater), giving me the full 8 channels on a sequencer, 
> which then switches to the next sequencer and so on, so we have in 
> effect one 24 channel sequencer, but the resetting of the A151 is 
> giving me a problem.
> Can anyone help please ?
> 
> 
> 
> 
> 
> 
> 
> 
>  
> Yahoo! Groups Links

Attachments

Move to quarantaine