AW: [Doepfer_a100] Gate Signals in A100

2005-06-08 by Dieter Doepfer

> -----Ursprüngliche Nachricht-----
> Von: Doepfer_a100@yahoogroups.com
> [mailto:Doepfer_a100@yahoogroups.com]Im Auftrag von fhrdh
> Gesendet: Mittwoch, 8. Juni 2005 11:42
> An: Doepfer_a100@yahoogroups.com
> Betreff: [Doepfer_a100] Gate Signals in A100
>
>
> Hello!
>
> i own an a100 suitcase cabinet with (still) just 3 modules.
> since a few weeks i own an acidlab bassline ( www.acidlab.de ), which
> is able to put out CV and gate. the cv is 1V/oct. -> no problem there.
> the gate signal is mentioned in the manual as +12V, which leads me to
> the question:
>
> is a +12V gate signal dangerous for the a100 modules, which handle
> usually +5V gate signals.

No. Each gate signal in the range +5V...+12V is OK for all A-100 modules.
Many modules (e.g. the envelope generators) can even be triggered with lower
voltages (~ +2...+3V). Only voltages beyond +12V can be dangerous for some
modules. It depends upon the gate input circuit if voltages beyond +12V
could damage the module. No problems occur e.g. with A-140, A-141 or A-142.
The switch based modules (e.g. A-148, A-150, A-151, A-152) may be destroyed
with gate voltages beyond the A-100 power supply (i.e. beyond +12V).

Best wishes
Dieter Doepfer