> If I'm not mistaken 8 S&H's and switches are required for a 4 stage analog > shift register (similar to the BBDs) as you need a n additional slave S&H > for each stage. I do not think, you need an additional slave S&H, if you decouple not only the s&h with the input selector, but also the trigger, which clocks the s&h. Florian > This is required to have the analogue value available to > forward it to the following stage as the preceeding S&H already is > "reloaded" from the stage before. A bit confusing but I think I'm right. > > The principle of the analog shift register would be this: > > > MSH1 -> SW11 -> SSH1 -> SW12 -> MSH2 -> SW21 -> SSH2 -> SW22 -> MSH3 ... and > so on > > with > MSH = main S&H of the stage > SSH = slave S&H of the stage > SWxy = switch > > The switches SWx1 and SWx2 have to be triggered with opposite phase: all > switches SWx1 are triggered simultaneously at the falling edge of the clock > signal to pass on the voltage of the main S&H (MSH) to the slave S&H (SSH). > All switches SWx2 are triggered simultaneously at the rising edge of the > clock signal to pass on the voltage of the preceeding slave S&H to the next > main S&H. > > How about a poll for such a module. Sounds interesting. > > Best wishes > Dieter Doepfer > > > > > > > Yahoo! Groups Links > > > > > > > -- Florian Anwander |ConSol Tel. +49(89)45841-133 |Consulting&Solutions Software GmbH Fax +49(89)45841-111 |Franziskanerstr. 38, D-81669 München email: florian.anwander@consol.de |http://www.consol.de
Message
Re: AW: [Doepfer_a100] Re: exotic new modules ideas anyone?
2005-06-08 by Florian Anwander
Attachments