Re: [Doepfer_a100] a171 vs a129/3 and a129/4

2005-06-28 by Bakis Sirros

hello bryan,
the a129/3 + a129/4 process(with vc-slew limiting)the
DC cv signals that come from the a129/1 analysis
section module. these are standard DC cv signals that
are used to control the 15 vca's(of the a129/2
synthesis section module) that come after the 15
filters of the a129/2.
so, this means that the a129/3+a129/4 combi can work
exactly like the a171. they both provide vc-slew
limiting for cv signals.
dieter correct me if i'm wrong.
best regards,
bakis.





--- Bryan E Cornell <bcor@loc.gov> wrote:

> Sorry, I got the wrong number in my last post.  I
> meant to say,
> 
> "Will the a129/3,4 do everything that an a171 will
> do?"  I'm talking about the vocoder submodules.
> 
> Bryan
> 
> 
> 


Bakis Siros
Parallel Worlds / Polariton
Athens-Greece
[Doepfer_a100] group owner