Hi >>The full set-up procedure is in the A-110 Service Manual, which is >>available at the Doepfer website (there's a link on the A-110 page). > Hmm... thanks but not very helpful, I do not wish to carry > out such a procedure, as I may make the matter worse with > the VCO. Then you heave to bring it to a shop, who gives service for Doepfer. Nevertheless it sould be quite easy: - switch off the A100 system - remove the screws from the A110 - do NOT disconnect the power of the A110, - cover the soldering side of the A110 with a piece of paper; you may fix it simply with an adhesive tape (This prevents unwanted shortages, though it is quite diffcult to destroy really something) - switch on the A100 and let it warm up a quarter of an hour. - set the "Tune" poti to center position. - take a small screw driver and tune the VCO with the trimmer "P6" (it is placed direct aside the writing "DOEPFER A110" on the pcb). - DO NOT TOUCH ANY OTHER TRIMMER! - switch off the A100 - remove the shielding paper on the A110's back - fix the A110 with the screws in the frame Best regards, Florian
Message
Re: [Doepfer_a100] Re: A-110 VCO calibration
2005-08-10 by Florian Anwander