Re: [Doepfer_a100] MCV4 and ARP Solus

2005-09-26 by nanobotdex

Excellent.  I will try switching it to +U and report back.

Thanks Dieter and Florian.

-Jeffrey

--- In Doepfer_a100@yahoogroups.com, Florian Anwander
<Florian.Anwander@c...> wrote:
> Hi
> 
> I once had a Solus and a Odyssey for restauration on my workbench. The 
> Solus I had did definitely not trigger below 9 Volts.
> 
> Florian
> 
> > should be no problem to control the Solus with the MCV4. You have
to set the
> > internal gate jumper to +U as at least the Odyssey cannot be
triggered with
> > +5V but requires at least ~ +8V gate level. A power supply with at
least 9V
> > (better 12V) should be used for the MCV4.