Re: a-190 probs

2005-10-17 by Jonathan Heslop

Figured some of this out myself. In Config - CV1 when you press a 
key you're selecting the lowest note on your midi keyboard. To 
access gate polarity, CV Char and Retrigger you need to send program 
change 1 - 6. There is no way to change them directly via the front 
panel. Okay. So all I need to do is send program change 6 from my 
Technics wsa1 or cubasis. I can't seem to get it to work though. 
When I send the program change do I need to have CV1 selected? Do I 
need to patch into the ADSR retrig/gate aswell?





--- In Doepfer_a100@yahoogroups.com, "Jonathan Heslop" <jon@p...> 
wrote:
>
> Hi, my first post. 
> 
> I bought a Doepfer A-100 from ebay a week or so ago. It finally 
> arrived yesterday and I have had fun fiddling with it. I'm 
suprised 
> at how easy it is to use, I have come up with a few sounds I quite 
> like. I did spend the first hour scratching my head as to why 
there 
> was no sound coming out of the machine, turns out two of the patch 
> cables supplied don't work :-) 
> 
> The one module that I can't get my head around is the A-190 MCVS 
> module. Channel, LFO Frq, Bend W, CV2 seem to work okay but the 
> Glide setting either does nothing or it changes the pitch of the 
> note I'm playing (I don't hear any glide though). CV1 under the 
> Config menu acts very strangely. As soon as I have it selected 
> (without pressing the Inc/Dec buttons) the gate signal seems to 
get 
> messed up, notes are either too short or they get stuck on. CV1 
> seems to be the only menu that has sub menus? I'm trying to 
> access "Retrigger", I'm hopeing this setting changes the way the 
> ADSR's behave . ATM an ADSR won't retrigger when you already have 
a 
> key pressed (I'm guessing it's currently set to off). 
> 
> I know you can change these settings via midi CC but I would like 
to 
> figure out how to change them via the front panel.
> 
> Any help would be great!
>