hello, don't think it's shorting anywhere inside the suitcase (it's got composite-plastic walls and aluminum railings which shouldn't affect even when touched), but i'll check anyway. it seems to happen only when i'm taking it somewhere (that's why i asked about moisture buildup) , when it happened yesterday (2 fuses, 1 after another:) i only saw a blink of led on a119. soooo.... could i _safely_ try a different variety of fuses?? somewhat desperately looking for answers ( Dieter ?). have a nice weekend all. cheers t > I'm not sure if this is the problem you are having, but some Doepfer > modules have PC boards *very* close to the edge of the module and it's > possible that the power traces are shorting out against your case. > This happened to me when I tried to install a certain Doepfer module > (either the Quad ADSR or Triple Bandpass, I can't remember which) in an > Asys RS15 euro-rack.... the traces on the lowest PC board touched > against the case and shorted out the whole system. The worst part is > that it fried 2 of my modules and I had to pay $180 to fix them. > Now I don't know if the Doepfer cases are the exact same dimensions as > the RS15, but you might want to check and see if any of your modules' > PC boards can touch the case under rigorous patching conditions. > Usually when a fuse keeps getting blown, there is an intermittent short > in the electrical system... or you are getting really bad power spikes > from your AC line. I assume you are using some sort of surge protector? [Non-text portions of this message have been removed]
Message
Re: [Doepfer_a100] Re: fuse issue (Correction)
2005-12-17 by tkrakowiak
Attachments