It's hard from the distance to find out what's wrong. Normally replacing all integrated circuits should solve the problem. But if there is a mechanical fault (broken part or cable) or a defective passive part (resistor, capacitor) it might be difficult to find the reason. I don't know what you mean concerning the A-110 serive manual. It is still online. I just tried it. Best wishes Dieter Doepfer > -----Ursprüngliche Nachricht----- > Von: Doepfer_a100@yahoogroups.com > [mailto:Doepfer_a100@yahoogroups.com]Im Auftrag von mritenburg > Gesendet: Samstag, 1. April 2006 03:38 > An: Doepfer_a100@yahoogroups.com > Betreff: [Doepfer_a100] Possibly broken A-110 > > > I aquired a used A-110 that does not output any signal. I have traced > the board with a scope and found a point near the BC559 marking that > outputs saw wave. I assume this is the output of the saw core. Since I > am not finding signal anywhere else on the board I swapped out both > TL064s. I have not swapped out the CA3046 I am curios what othe > critical components I should look at to narrow down my search. Any > particular transistors or Electrolytic caps. Also, what happened to > the A-110 sevice manual that used to be on the doepfer site? > > Thanks! > > Matthew > > > > > > > Yahoo! Groups Links > > > > > >
Message
AW: [Doepfer_a100] Possibly broken A-110
2006-04-03 by Dieter Doepfer
Attachments