Re: [Ensoniq-VFX-SD] Digest Number 380

2003-09-23 by Joe McMahon

On Tuesday, Sep 23, 2003, at 10:21 US/Eastern, 
Ensoniq-VFX-SD@yahoogroups.com wrote:
>    From: "Simon Rod." <stek@...>
> Subject: Re: Digest Number 376
>
>
>
>> "Why are there "hitches" at the end of sequence tracks sometimes?").
>
> yeah that's a good one - why does this happen sometime?
>
>

The other reason is that the sequencer OS is juuuust a bit sloppy 
sometimes. You should always check the note-off time of the last note 
in any sequence that "hitches" either on repeat or when used in a song. 
You will find that every once in a while the last note actually ends 
partway into the (non-existent) measure following the end of the 
sequence.

For instance, the last note's note-off in a 16-bar sequence might show 
up at something like 17.0.13. The solution is to trim that note back to 
16.4.96 in the event editor. Voila, no hitch.