We have received a number of M10's back and in turn a few blog missles regarding a dead recycle (LFO) mode, While I cannot speak for users who did not elect to return theirs, in ALL cases for those who did D4 (diode 4) was blown, meaning an external Trigger was inserted while the unit was in self oscillation. This is a dangerous habit. Please recycle reasponsibly...LOL! '-P