Yahoo Groups archive

QTR-Quadtone RIP

Index last updated: 2026-04-28 23:12 UTC

Message

Re: [QuadtoneRIP] digital negative - linearization problem

2014-05-30 by may Date

Sorry that I just found the "Drop-Quad-Profile" script on mac version. I can't use QTR on mac because it can't find the printer (EPSON 3885),but it works on windows if I save the profiles in the directory of 3880UC.


Daisy






On Thursday, May 29, 2014 8:29 PM, "bjdaisie@... [QuadtoneRIP]" <QuadtoneRIP@yahoogroups.com> wrote:





 
I got the linearization info as below for the reading of step-21X4-random stepwedge:
 
Step Dens Lab A B 
0.00 0.086 92.57 0.04 5.04 -                             a                   b    L    +
5.00 0.090 92.22 0.15 5.36 -                             a                    b   L    +
10.00 0.099 91.52 0.29 5.64 -                             |a                    b L     +
15.00 0.114 90.25 0.55 6.29 -                             | a                     Lb    +
20.00 0.132 88.84 0.82 6.73 -                             |  a                   L  b   +
25.00 0.162 86.44 1.20 7.44 -                             |   a                L       b+
30.00 0.197 83.73 1.59 8.00 -                             |     a             L         b
35.00 0.248 79.88 1.98 8.37 -                             |      a         L            b
40.00 0.294 76.52 2.21 8.49 -                             |       a      L              b
45.00 0.346 72.98 2.35 8.30 -                             |        a   L                b
50.00 0.420 68.01 2.43 7.87 -                             |        aL                   b
55.00 0.497 63.24 2.32 7.12 -                             |      L a                  b +
60.00 0.600 57.20 1.90 5.50 -                             |   L  a              b       +
65.00 0.710 51.28 1.31 3.57 -                             L    a        b               +
70.00 0.793 47.11 0.76 1.86 -                           L |  a   b                      +
75.00 0.893 42.45 0.30 0.40 -                        L    |b                            +
80.00 0.974 38.95 0.01 -0.65 -                      L   b  a                             +
85.00 1.055 35.59 -0.17 -1.35 -                    L  b    a|                             +
90.00 1.115 33.28 -0.24 -1.80 -                  L  b      a|                             +
95.00 1.173 31.13 -0.23 -1.91 -                 L   b      a|                             +
100.00 1.221 29.46 -0.15 -1.77 -                L    b      a|                             +
 
LINEARIZE="92.575 92.22 91.52 90.2525 88.8375 86.44 83.7275 79.875 76.5225 72.9775 68.01 63.2375 57.205 51.2775 47.11 42.4475 38.945 35.595 33.28 31.13 29.4575"
 
For Digital Negative:
LINEARIZE="29.4575 31.13 33.28 35.595 38.945 42.4475 47.11 51.2775 57.205 63.2375 68.01 72.9775 76.5225 79.875 83.7275 86.44 88.8375 90.2525 91.52 92.22 92.575"
 
---------------------------------
 
Then I pasted the LINEARIZE data for Digital Negative into my previous ink description file. And in "Curve Creator" of QTRgui, I opened the file and clicked on  the "show curve" and got the message:
Invalid linearize curve - not constantly increasing. Curve Creation failed.
 
And it's so puzzling if I pasted the LINEARIZE data NOT for Digital negative, it could be linearized.  
 
And in the document of "QTR 2.7&Eye-One spectrophotometer", it reads:
The last line has the linearization info. Triple-click on it, Copy the whole line and Paste it to the bottom of the ink description file. Re-process the ink file with Drop-Quad-Profile.
 
Sorry to tell that I couldn't even find Where "Drop-Quad-Profile" is.  
 
I have also scanned the step-21X4-random stepwedge,read the k value of the first line,made a correction curve for negatives in PS and put it in the ink description file as Gray-curve. But the result seems worse than before. For example, I got K values of 68 for the patch of 70 without the Gray-curve, but now a K value of 50.
 
Really don't know what to do. Any suggestions would be highly appreciated!!
 
 
Daisy

Attachments

Move to quarantaine

This moves the raw source file on disk only. The archive index is not changed automatically, so you still need to run a manual refresh afterward.