Yahoo Groups archive

QTR-Quadtone RIP

Index last updated: 2026-04-28 23:12 UTC

Message

Re: weak blacks in 1400/Cb6 setup

2015-10-25 by paulmwhiting@...

found it! I forgot I had downloaded the full set of profiles, must have been from Paul's or Roy's website:

(I haven't tried making my own profile or relinearizing this one.)

#Notes www.PaulRoark.com 11-8-2011
PRINTER=Quad1400-MIS
CURVE_NAME=Eb6-RedRivAurora-11-2011
GRAPH_CURVE=YES
N_OF_INKS=6
DEFAULT_INK_LIMIT=45
BOOST_K=45
LIMIT_K=40
LIMIT_C=
LIMIT_M=
LIMIT_Y=
LIMIT_LC=
LIMIT_LM=
N_OF_GRAY_PARTS=6
GRAY_INK_1=K
GRAY_VAL_1=100
GRAY_INK_2=C
GRAY_VAL_2=70
GRAY_INK_3=M
GRAY_VAL_3=42
GRAY_INK_4=LC
GRAY_VAL_4=23.7
GRAY_INK_5=LM
GRAY_VAL_5=18.5
GRAY_INK_6=Y
GRAY_VAL_6=6.8
GRAY_HIGHLIGHT=10
GRAY_SHADOW=10
GRAY_OVERLAP=
GRAY_GAMMA=1
GRAY_CURVE=
N_OF_TONER_PARTS=0
TONER_HIGHLIGHT=10
TONER_SHADOW=10
TONER_GAMMA=1
TONER_CURVE=
N_OF_TONER_2_PARTS=0
TONER_2_HIGHLIGHT=10
TONER_2_SHADOW=10
TONER_2_GAMMA=1
TONER_2_CURVE=
N_OF_UNUSED=0
LINEARIZE="96.84 94.4 91.16 86.34 82.06 77 72.12 67.02 62.18 57.92 53.77 50.12 46.55 42.24 38.39 34.95 31.87 28.9 26.3 22.85 19.98 "