Yahoo Groups archive

QTR-Quadtone RIP

Index last updated: 2026-04-28 23:12 UTC

Message

Re: [QuadtoneRIP] Epson P800 QTR digital negative starting point

2016-07-29 by FELIX MARTIN

Hi Phil

any news from your part?
I would be very interested of your progress.

If you want to contact me directly, do so at felix@... <mailto:felix@...>



> On Jul 26, 2016, at 9:38 PM, Keith Schreiber keith@jkschreiber.com [QuadtoneRIP] <QuadtoneRIP@yahoogroups.com> wrote:
> 
> Hi Phil,
> 
> 
> I’ve been working on profiles with an artist who is printing Pt/Pd on a variety of tricky Japanese papers and was looking to improve her digital negs. She was trying to make profiles using a scanner to read the values and having all sorts of problems. Someone referred her to me for help. She had a 3880 when we started but it suffered a catastrophic failure midway through the profiling process. She replaced it with a P800. We started from the beginning again with the 3880 base profile, made a couple of minor adjustments, and ended up with a good base profile for the P800. I am happy to share it with you. It is for the P800 with the stock Epson inks. You will have to print with it, analyze the results (preferably with a spectro or densitometer), and create your own Gray Curve for your specific paper and chemistry. 
> 
> Copy and paste into a text file, change the notes to reflect your details, and change the curve name to something that is meaningful to you. The main difference between this and my 3880 base profile is the Gray Gamma setting. 
> 
> ~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~
> #Notes Profile for Pd 2.5% Na2 AC ~75F on Shikibu Gampi
> 
> PRINTER=QuadP800
> CURVE_NAME=MV_P800PK-UPOHP-Pd-AC-ShikibuGampi
> GRAPH_CURVE=YES
> 
> N_OF_INKS=8
> DEFAULT_INK_LIMIT=60
> BOOST_K=60
> LIMIT_K=60
> LIMIT_C=5
> LIMIT_M=5
> LIMIT_Y=12
> LIMIT_LC=5
> LIMIT_LM=5
> LIMIT_LK=60
> LIMIT_LLK=80
> 
> N_OF_GRAY_PARTS=3
> GRAY_INK_1=K
> GRAY_VAL_1=100
> GRAY_INK_2=LK
> GRAY_VAL_2=40
> GRAY_INK_3=LLK
> GRAY_VAL_3=10
> GRAY_HIGHLIGHT=2
> GRAY_SHADOW=6
> GRAY_OVERLAP=
> 
> GRAY_GAMMA=0.8
> 
> GRAY_CURVE="0;0 100;100"
> 
> N_OF_UNUSED=0
> COPY_CURVE_C=K
> COPY_CURVE_M=K
> COPY_CURVE_Y=K
> COPY_CURVE_LC=LK
> COPY_CURVE_LM=LK
> ~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~
> 
> Feel free to contact me directly if you’d like.
> 
> Keith
> 
> Keith Schreiber
> jkschreiber.com <http://jkschreiber.com/>
> 
> 
> 
> 
>> On Jul 26, 2016, at 6:39 PM, philbond87@... <mailto:philbond87@yahoo.com> [QuadtoneRIP] <QuadtoneRIP@yahoogroups.com <mailto:QuadtoneRIP@yahoogroups.com>> wrote:
>> 
>> 
>> Does anyone have a basic starting point for a P800?
>> 
>> Would starting with a profile for a 3880 – and modifying it based on output – be a reasonable way to proceed?
>> 
>> 
>> 
>> Thanks!
>> 
>> 
> 
> 
>