--- In QuadtoneRIP@yahoogroups.com, "David Meddings" <meddings@...> wrote: > > Hi, I just sprung for an Eye One Photo kit so I can linearize and do > my own icc profiles. > > Having a little trouble getting started. I've installed ProfileMaker > and placed the test chart ref files in the appropriate directory. As > per the pdf instructions in the Eye One folder I selectd the QTR-21- > random test chart for my first attempt. > > This brings up a very small window with a very small 21 strip wedge > (my monitor resolution is 1600x1200). A dialog box tells me to stick > the Eye One on the white reference. I assume this means the white > reference chip in the base of the Eye One instrument holder, so as > long as that's right I should be calibrated correctly. Dave, You need to PRINT the QTR-21-random test chart. Then read with the Eye One. Don't know if you are on Windows or Mac. Mac has text paper profiles that are easy to edit. To re-linearize delete the complete line like this in the original paper profile: LINEARIZE="0.029 0.077 0.141 0.217 0.299 0.379 0.469 0.554 0.643 0.732 0.816 0.891 0.969 1.048 1.133 1.219 1.308 1.390 1.469 1.569 1.664 " Turn off all color management in Photoshop and print test chart using QTR. Let dry for a few hours or use a hair drier for a few minutes and read with Eye-One. Copy and past new linearization output from Eye-One/QTR script into paper profile.
Message
Re: Need help getting started with Eye One
2006-07-23 by John Vitollo
Attachments