Hi John, It recognizes headings of either RGB or RGB_R. The values should be 255 (white) through 0 (black). Density numbers are fine, values are between 0 and 4. It's much easier to try it than figure it out. Roy On Wednesday, August 2, 2006, at 03:26 PM, john eckenrode wrote: > Hi Roy > Regarding the information below. Will > QTR-Linearize-Data and QTR-Create-ICC take density > measurements measured in RGB_R. > My densitometer gives these measurements. > So what I am wondering is if at a given grey % can I > enter RGB and Density values and have Create-ICC > understand it. If yes, how would I enter that info, ie > does Create-ICC recognize RGB columns? > Thanks > John E > > The important columns are: >> 1) Gray -- 0 to 100, basically the same as K in >> Photoshop. >> or RGB -- 255 to 0, can be used as a >> substitute for Gray. >> if missing it assumes N evenly spaced samples >> 2) L, LAB, LAB_L -- > 0 to < 100, the L >> measurements >> 3) A, LAB_A -- A measurements (optional, A=0 if >> not there) >> 4) B, LAB_B -- B measurements (optional, B=0 if >> not there) >> or D, Density -- 0 to 4, density instead of L >> values, but no color >> then. > > > > Yahoo! Groups Links > > > > > > > - Roy Harrington roy@... Black & White Photo Gallery http://www.harrington.com
Message
Re: [QuadtoneRIP] Eye-One / Measure Tool - file asked
2006-08-03 by Roy Harrington
Attachments