Good day everybody, My apologies if the answer to these questions have appeared somewhere in the postings; I did do a search so please humour this newbie with a reply. I just installed QTR and a UT& inkset on an Epson 2200. I am following the instructions in the QTR manual and printed an inkseparation page. For determining the percentage of black to create 100% light black I will use an old Barbieri densitometer I have. I am a bit puzzled though about the remarks that for Ultrachrome inks you only have to do this for black/light black but that for Quadtone inks you need to repeat it for each process. Does this also apply to UT7 inksets? If so, how do I go about? Compare light magenta position to magenta position and then convert to a density relative to black ? Comparing densities of the magentas is not a problem, but how would I convert to a density relative to black? Something else I will be trying Fibaprint Gloss with PK and GLOP in yellow position. Would anybody have a curve that I can use as a starting point? Thank you in advance for any assistance. Peter