GO here:
http://www.blacet.com/store2.html
it lists the power consumption by module (last column). this stuff ain't so
bad...the VCOs only pulling 50ma.
Michael A. Firman wrote:
http://www.blacet.com/store2.html
it lists the power consumption by module (last column). this stuff ain't so
bad...the VCOs only pulling 50ma.
Michael A. Firman wrote:
>
>
>
> The Blacet stuff (in general) has no LEDs (There are exceptions but mostly
> there aren't a lot of them on the system). Having LEDs on the system seems
> to really pull the juice. That said though, I think that the VCOs pull a lot
> of
> current and they don't have any LEDs on them.
>
> --- In SergeModular@yahoogroups.com, Peter Grenader <peter@b...> wrote:
>> Yup!
>>
>> It's kinda odd though - my experience, Blacet stuff is real power efficient.
>> I was running 9 of them form a single 750 Ma supply for the longest time .
>> Your three modules are probably not pulling more than 150 ma's between the
>> lot, even when they're doing their thing to the max.
>>
>> Blake Wilson wrote:
>>
>>>
>>> At 9:30 AM -0800 2/2/05, Peter Grenader wrote:
>>>> You're probably not going to find a single supply with both +/- 12 and 15
>>>> volt taps - I'v e seen 12 and 24, but not what you're asking about. I
>>>> recommend a couple of things:
>>>>
>>>> 1) Buy a 15 volt supply and run you're system with two. nothing wrong
>>>> with
>>>> that. The Blacet supplies are great, but Condors are really really great,
>>>> but if you go with Condor, you're going to have to futz with the chassis
>>>> box
>>>> and wiring it up and given you're dealing with both primary and secondary
>>>> currents, I wouldn't recommend that unless you're really comfortable with
>>>> this sort of thing.
>>>>
>>>> 2) Buy a 15 volt supply and fit it with a +/-12 volt regulator pair and
>>>> you
>>>> won't need to use the Doepfer supply, although I beg you contact Analog
>>>> Haven to find out what will come of your D warranty if you run those off a
>>>> non D supply. I know you will void your Analogue System warranty doing
>>>> this.
>>>
>>> thanks, peter. option two is precisely what i'm doing right now: i
>>> have an old blacet 15 v supply and i built a little board with a
>>> couple 7812 vr's and run those rails to the doepfer/Asys stuff. but
>>> the blacet ps is choking and i was hoping to use the serge to power
>>> the system, but, of course, the blacet won't work that way. i think i
>>> might rewire things to use the big serge to run the doepfer/etc, and
>>> allow the blacet to corner their own supply. that would work.
>>>
>>> thanks,
>>>
>>> blake
>
>
>
>
>
>
> Keep on Patchin'!
>
> Yahoo! Groups Links
>
>
>
>
>
>
>