Yahoo Groups archive

SergeModular

Index last updated: 2026-04-28 23:13 UTC

Message

Re: SSG Operation Question - Help!

2008-01-07 by matthew carpenter

Hi,
Try this:
Patch white noise to Stepped IN and a DTG or DSG in Cycle mode (or with TRIG patched to GATE) to Stepped SAMPLE. Stepped RATE knob should be fully clockwise. Now the light should be blinking!

Matt

On 1/6/08, legion01x <legionhwp@...> wrote:

I am trying to use the Smooth stepped generator module and I can't seem
to get anything out of the bottom half. I've read the wizardry pages at
Egres but am coming up blank.

I'll be the first to admit I don't fully understand this module but I
can't seem to get any CV or audio out of it and the light never goes
on. The Smooth part on the top seemto be working ok although again i
don't fully know what it does. at least I can get sound and the light
blinking on that.

Can anyone tell me a quick patch or two with the Stepped generator part
so I can verify it's working right? Perhaps something with on VCO or
even an internal patch. At least something to make sure it's accepting
a sigal and the light is triggering, etc.

Please be patient as I'm not even sure exactly what are inputs and
outputs for what on this thing. Then again I guess that's half the fun.

All help GREATLY appreciated.

Thanks!


Attachments

Move to quarantaine