Looking at the schematics, you only need to have black and orange ( or pink for 220V ) connected to the fuse/mains switch. This should work. If it doesn\ufffdt the transformer could be toast. You can get a new one at Elfa. WT ----- Original Message ----- From: "xylofoam" <lars.frisk@...> To: <Simmons_Drums@yahoogroups.com> Sent: Monday, October 03, 2011 1:58 PM Subject: Re: [Simmons Drums] Voltage conversion of the MTM transformer... ? > Hehe :-D > > // L > > --- In Simmons_Drums@yahoogroups.com, jesper <jesper@...> wrote: >> >> xylofoam skrev 2011-10-03 10:20: >> > Hi all, >> > >> > I'm trying to convert the original transformer in my MTM unit from 110V >> > to 240V... According to the service manual the transformer supports all >> > voltages on the primary core (all colours match the schematics >> > (black:0V, brown:100V, white:110V, pink:220V and orange:240V)), but >> > when >> > I reconfigure the tranfsformer to EU (240V) I get absolutely NOTHING on >> > either of the secondaries?! >> > What am I doing wrong? According to the schematics there is only ONE >> > primay core, but are there really TWO that needs to be in serial, or ? >> >> Sell it to me instead. I have 110-feeds to spare. :D >> >> -- >> electronically yours, jesper >> >> - -- --- ---- ----- ---- --- -- - >> www.electronic-obsession.se >> > > > > > ------------------------------------ > > Yahoo! Groups Links > > >