ZO results using the Varisync function. MOTM VCO triangle to ZO Varisync input. Varisync set to 1, soft sync. Range switch: Lowest setting Bias switch: High Tuning Knob in middle of range Desired Voltage Input Voltage Desired Frequency Actual Frequency Error (Hertz) Error (percent) -1 -1.0007 15 15.039 0.039 0.26% 0 -0.0034 30 30.25 0.250 0.83% 1 0.9940 60 60.17 0.170 0.28% 2 1.9915 120 119.99 -0.010 -0.01% 3 2.9887 240 240.09 0.090 0.04% 4 3.9862 480 480.2 0.200 0.04% 5 4.9837 960 959.87 -0.130 -0.01% 6 5.9820 1,920 1916.7 -3.300 -0.17% Results are much better, as the ZO tracks the MOTM VCO frequency. I have not checked the audible difference between modulating this ZO configuration and the one without soft sync. These measurements are with an unmodulated ZO. John Loffink The Microtonal Synthesis Web Site http://www.microtonal-synthesis.com The Wavemakers Synthesizer Web Site http://www.wavemakers-synth.com > -----Original Message----- > From: The_Cyndustries_List@yahoogroups.com > [mailto:The_Cyndustries_List@yahoogroups.com] On Behalf Of John Loffink > Sent: Monday, February 27, 2006 11:22 PM > To: The_Cyndustries_List@yahoogroups.com > Subject: RE: [The_Cyndustries_List] ZO 1V/Octave calibration > > My results. > > I used the preferred ZO setting for accuracy per the manual. I did not > adjust the ZO 1V/oct tracking trimmer. It is at the factory setting. > > Range switch: Lowest setting > Bias switch: High > Tuning Knob in middle of range > > Encore Expressionist used as the voltage source. Both VCOs patched to > 1V/oct jacks. Measured frequency on sine out. No other cables plugged > in, > all modulation controls at minimum. Both VCOs in the same cabinet running > from the same power supply. > > I set the VCO tuning as accurately as I could to 120 Hz at the 2 volt > input. > This is the reference frequency. > > MOTM VCO calibrated by me recently. > > Measurements with Extech Multimaster 560 5/6 digit DMM. Voltage accuracy > is > rated at +/- 0.03%. Frequency accuracy is rated at +/- 0.008%. > > ZO data > > Desired Voltage Input Voltage Desired Frequency Actual Frequency > Error (Hertz) Error (percent) > -1 -1.0007 15 14.812 -0.188 -1.25% > 0 -0.0034 30 30.16 0.160 0.53% > 1 0.9940 60 60.308 0.308 0.51% > 2 1.9915 120 119.99 -0.010 -0.01% > 3 2.9887 240 238.16 -1.840 -0.77% > 4 3.9862 480 472.2 -7.800 -1.63% > 5 4.9837 960 934.25 -25.750 -2.68% > 6 5.9820 1,920 1841.7 -78.300 -4.08% > > MOTM-300 data > > Desired Voltage Input Voltage Desired Frequency Actual Frequency > Error (Hertz) Error (percent) > -1 -1.0007 15 14.965 -0.035 -0.23% > 0 -0.0034 30 29.958 -0.042 -0.14% > 1 0.9940 60 59.954 -0.046 -0.08% > 2 1.9915 120 119.96 -0.040 -0.03% > 3 2.9887 240 239.89 -0.110 -0.05% > 4 3.9862 480 479.68 -0.320 -0.07% > 5 4.9837 960 958.23 -1.770 -0.18% > 6 5.9820 1,920 1912.1 -7.900 -0.41% > > For comparison, Synthesizers.com VCO data from their web site, not > measured > by me, uses 128 Hz as based frequency. > > Desired Frequency Actual Frequency Error Hertz Error > Percent > 32 32.07 -0.07 -0.22% > 64 64.16 -0.16 -0.25% > 128 128.2 -0.20 -0.16% > 256 256.2 -0.20 -0.08% > 512 511.9 0.10 0.02% > 1,024 1023.2 0.80 0.08% > 2,048 2046 2.00 0.10% > 4,096 4094 2.00 0.05% > 8,192 8236 -44.00 -0.54% > 16,384 16778 -394.00 -2.40% > > I hope the ASCII tables don't become too jarbled. > > John Loffink > The Microtonal Synthesis Web Site > http://www.microtonal-synthesis.com > The Wavemakers Synthesizer Web Site > http://www.wavemakers-synth.com >
Message
RE: [The_Cyndustries_List] ZO 1V/Octave calibration
2006-02-28 by John Loffink
Attachments
- No local attachments were found for this message.