Re: Updated! ZEROSCILLATOR TESTING PROCEDURE Version 2.0

2006-08-05 by tuninghead

Hi all you Zeroscillinos,

Cynthia did a great job condensing the testing and adjustment
procedure into this document.  However, I noticed a tiny error in step
16 and in the interest of correctness and completeness, I type the
following:

[ALERT: ADJUSTMENT CAN CHANGE 1V /OCTAVE CALIBRATION] does not apply
here.  Adjusting the quadrature shape control has no effect on the
1V/oct calibration.

Also, a word about turning any of the trimmers, and that is, you
probably don't have to.  All important voltages within the ZO are
derived from a precision reference and unless you work on Mercury or
Pluto, you probably won't have to turn anything.  The exception may be
the 1v/oct trimmer in order to match your (uncalibrated) equipment. 
Ahem.  And remember, let the thing warm up and settle before you
consider doing anything.

Just my $1/50,
--Mark Barton


> 
> 16. TEST: QUADRATURE (Advanced Procedure!)
> 
> [ALERT: ADJUSTMENT CAN CHANGE 1V /OCTAVE CALIBRATION]
> 
> Please Return to the Initial Set-up Conditions above in lines number
1 & 2.
> 
> Turn both the MORPH_A and the MORPH_B Knob to full CCW or closest
> to the TRIANGLE Icon next to the knob.
> 
> Have look at the MORPH_90 Output on a scope and adjust trimpot VR501
> (labeled QUADRATURE and located on the end of CYN109-B the bottom
> PC board in the three-board sandwich).
> 
> Play "pin the top on the mountain" with the trimpot until the
triangle looks
> complete.
> 
>