RE: [analogue-sequencer] Func+Run issue

2005-10-17 by Colin f

> Using the P3 to control a Roland MC-80(as midi slave), Func+Run works
> ok as a Midi Continue BUT on first GBAR it seems to send out a Midi
> Start because the MC-80 resets to Bar 1.  This only began occuring
> after I upgraded from 3.1.06B10 to B18.
> 
> Is there a work round for this?

FUNC+RUN while stopped will CONTinue, FUNC+RUN while already running will
restart MIDI clock by sending a STOP then a START at the next GBar reset. 
The current build will need to ignore the held FUNC+RUN once it starts to
prevent it being treated as a restart.
I'll fix this and upload a new beta.

Best regards,