Chiel, > i'm on beta 25 at the moment, and I've just loaded in all the material > for a liveset i'm doing tomorrow. I was trying some stuff out, and > there's something very wrong with the "randomize Aux[x]" event; I have > it set to a value of 1, but it always outputs a value of 127. Well spotted... That one crept in on the 7th of last month, when I 'fixed' an existing bug with the 'rndmz aux n' events overflowing. It's definitely fixed in beta 27, which you'll find in Yahoo files now. The previous fault with these events was that if the total result of the aux value plus the random addition exceeded 127, the aux was deactivated. This had been in there since those events first appeared... funny no-one noticed, though I guess the deactivation would probably be quite intermittent, so you'd need to pay close attention. The fixed behaviour is that a result exceeding 127 is clipped to 127. The bug you saw was because of an extra ampersand in the top bit test. Best regards, Colin Fraser Sequentix Music Systems Ltd http://www.sequentix.com