2006-01-23 by colinfraser_com

Folks,

Another slight update in Yahoo files...
One bug fix Paul picked up, though it's a pretty obscure one related 
to changing MIDI channels with events during a tied note.

Plus this build adds the 'rvtz' (reverse to zero) accumulator 
behaviour, and renames 'rvrs' (reverse) to 'rvbp' (reverse bi-polar), 
as discussed a few days ago.

'rvtz' allows values in the range 0 to <accumulator limit>.
'rvbp' allows values in the range +/- <accumulator limit>.
Both modes reverse the 'rel' direction as the value reaches the limits.