> I had almost exactly the same issue with an older P3 last week. I was > using MidiOx as well and got the BAD DATA messages when sending the > upgrade. I tried a few times to no avail. When P3 receives a firmware block, it takes a little while to decode and write it into the flash ROM. When it's done the writing, it sends a handshake message. MIDI Ox doesn't wait for handshake messages, so it needs to put a long enough gap between blocks so that the writing is finished before it sends the next block. P3 Tools waits for the handshake message, so it will send the code as fast as P3 can write it, but no faster. To set up the correct delay in MIDI Ox: Start Midi Ox Go to "View", "Sysex..." In the Sysex View and Scratchpad window, go to "Sysex", "Configure..." Make sure the "Delay after F7:" checkbox is ticked, and enter a delay of 100ms Click "OK" to go back to the sysex window, then you can send the sysex file Alternatively, you can use the MID file version of the firmware, and play it with Windows Media Player, or a.n.other midi file player. The MID file has the delay encoded into it. Best regards, Colin Fraser Sequentix Music Systems Ltd http://www.sequentix.com