> i'm having problems with the new update. At the end of the > sysex send > i get an error message (code CHK Error!). The P3 still can still be > booted up after this and it seems to be working fine but i couldn't > say for sure. There was an issue with a CPU configuration flag that meant early versions of the bootloader for the production P3 CPUs couldn't load a main program over a certain size. Update to the latest bootloader version using the files p3-bootloader-v3.3-AT... and you'll be able to load the whole program. Part of the image will be missing in your current state, so certain things will not work. > Now for my main gripe. I'm using this with a virus classic so it > could be it that has the problem. Basically i'm finding that when > using the gates set at thirteen some notes are not getting properly > restarted. In fact it seems to be random when the notes restart. Its > as though i have a random mask setup on the ties, but i don't. > This is when i have my synth on patches where i have them set to so > the envelopes doesn't retrigger if the notes are tied. > I hope you know what i mean by this, its kind of difficult to > explain > clearly. If you like i can send you a short repeating loop so you > could hear what i mean. Might be useful if you could send me a dump (or text listing) of a pattern giving you the problem. I'll look at the output in MIDI-Ox. Best regards, Colin Fraser Sequentix Music Systems Ltd http://www.sequentix.com
Message
RE: [analogue-sequencer] New update problem
2006-06-04 by Colin f
Attachments