Yahoo Groups archive

Analogue-sequencer

Index last updated: 2026-04-28 23:15 UTC

Message

RE: [analogue-sequencer] 'Set Step Value' useage with new 'Drone' feature

2006-06-09 by Colin Fraser

> I was trying to find a way of having the 'length' of a single step be 
> equal to 13 on the fourth bar of a repeating 16 step sequence (and 
> equal to 7 on the other 3 passes). I decided that the best way to do 
> this would be to use the  'Set Step Value' aux event to set a value 
> of 13 and then use an acumulator mask to mask the 'Set Step Value' 
> aux event.  I ran into a problem in that the 'Set Step Value' event 
> has a max value of 12.  Am I doing something wrong here or is this 
> likely a bug ?

The implementation of length 13 is not finalised, and I haven't updated the
'set length' event yet.

The aux values are always stored as a number from 0 to 127.
The value is scaled to the required range depending on which event is
selected.
If I were to change to range of the 'set length' event to 13, existing
patterns which had values of 12 in there could then become 13.
So the final implementation of 'drone' will need a caveat that any 'set
length' values may need to be revisited.

Best regards,
Colin Fraser
Sequentix Music Systems Ltd
http://www.sequentix.com