Yahoo Groups archive

Analogue-sequencer

Index last updated: 2026-04-28 23:15 UTC

Message

RE: [analogue-sequencer] Certain Bank/Parts have all steps set to skip

2008-09-16 by dave@RenegadeRhythms.com

Thanks.. I was just about to try that...

One thing, I've been checking it out today, and determined
that all the odd banks are gone and all the even banks work fine.

I'll follow up with if resetting it has helped at all...

Thanks,

Dave

On Mon, September 15, 2008 3:21 pm, Colin Fraser wrote:
> Dave,
>
>
> Your memx problem does sound like a hardware issue to me.
> First thing I would try would be to re-seat the memx board in the RAM
> socket. A big enough knock to the P3 in just the right direction could have
> moved it. Take the mainboard out when you do it, just to be sure you can
> see that all the pins are firmly in the socket.
>
> Best regards,
> Colin Fraser
> Sequentix Music Systems Ltd
> http://www.sequentix.com
>
>
>
>