2004-01-19 by Robert van der Kamp

On Monday 19 January 2004 15:22, Paul.Maddox@synth.Net 
wrote:

> just a thought..
> I had a problemw tih mine, it kept showing step9, as
> constantly changing. I couldn't adjust any of the other
> values and it just showed '9' all the time..

Looks like my problem!

> I resoldered the pot, swapped the 4051, it STILL did it..
> The I discovered that I had not put the connector from
> the pot boards to the motherboard correctly...
> Fixed this and bingo, life was good again...

Ah. Correctly how? You mean the polarity was wrong? Or did 
you just had to push in better?

- Robert