Yahoo Groups archive

Analogue systems

Index last updated: 2026-04-28 23:15 UTC

Message

Re: Modding the RS200

2003-04-18 by (i think you can figure that out)

in regard to adding banks to sequencers:

You can do this, given the drive method that supplies the pots 
(the outputs of the final counter which is being gated by the 
banks) isn't near it's maximum load.

The pots and pulse banks themselves aren't so much the culprit 
- it's the pulse out are, as they go to the outside world and can, in 
theory, be loaded down to the point  they crap out.  

If one wished to expand the number of banks, I would suggest 
they insert a current amplifying buffer on the buss BEFORE the 
new pots which will be added.  The CD4050 works quite well for 
this and has enough jiuce to power 15 banks quite easily.

So, to do this you would need to run the counter outs through a 
4050, then through the pots - one side of the pot to the 4050 out, 
the other to ground, the wiper to a summing resistor to the final 
summing amp, where the outputs of all of the 16 pots are 
combined.

Make sure you duplicate the summing amp configuration from 
the factory installed banks, or your response will be different in 
the ones you add.