Hi guys,

could anyone having this module give me some advice ?
I would just like to know what the behaviour of OUT A & OUT B should be.

I read the manual from the module. From what I understand OUT A & OUT B should give the same as SIG-OUT but with an added inversion or non inversion of the TRAPEZOID EG ?

SIG OUT works fine for me
If I take the same patch but use OUT A or OUT B ( and the level at it's max left or right) I get a huge pop/click when the attack starts and a very faint patch sound. Only the center seems to work fine, giving no output :p

Another issue I'm having is with the OFF Mode, in the manual it says you can make delays with a max of 5 s. The pot works fine for me till it gets to level 6, I turn it a mm further and it's like I've put it on the max level or 10...I get no repetition of the EG once past 6. Shouldn't this be occuring at level 10 ?

Thx for helping me out here