Bc2000 (for the BCF2000 & BCR2000) group photo

Yahoo Groups archive

Bc2000 (for the BCF2000 & BCR2000)

Index last updated: 2026-04-28 23:16 UTC

Message

Re: BCR2000 NRPN question / BC Manager download?

2009-06-25 by andi_k_81

Just an update - my BCR2000 arrived and I am quite happy with it.

Regarding the BCN44-NRPN-Bug and support of negative NRPNs in BCN44 and BCR2000, I sent a bug report / feature request to Behringer Germany via http://www.behringer.de/EN/Support/Online-Support.aspx 

They instantly (!) replied that they forwarded it to the development team....

I'm not sure if this is enough for them to create firmware updates, so I'd like to encourage other BCN44 / BCR2000 / Micron owners to contact Behringer as well.

Cheers,
Andi



--- In bc2000@yahoogroups.com, "andi_k_81" <a-v-a-t-a-r@...> wrote:
>
> Hi all!
> 
> I am new to the group, my name is Andi (hello Andi). I own the BCN44 and mainly use it standalone to program my synths / MultiFX units.
> 
> What keeps me from buying the BCR2000 is a bug that renders the BCN44 pretty useless for control of my Alesis Micron and I am afraid that the BCR2000 has the same issue. (I know about the negative NRPN issue and also would love to have a mode where the encoders work contineously through 16284..16383,0,1..127. But this is not the point here.)
> 
> In NRPN/Abs14 mode, the BCN44 does not send Data Entry MSB correctly but skips every odd number, i.e.
> 
> values displayed: 0..127 
> -> values sent: MSB 0, LSB 0..127 -> real NRPN 0..127
> values displayed: 128..255 
> -> values sent: MSB 0, LSB 0..127 -> real NRPN 0..127!!
> values displayed: 256..383 
> -> values sent: MSB 2, LSB 0..127 -> real NRPN 256..383
> values displayed: 384..511 
> -> values sent: MSB 2, LSB 0..127 -> real NRPN 256..383!!
> values displayed: 512..639 
> -> values sent: MSB 4, LSB 0..127 -> real NRPN 512..639
> values displayed: 640..767 
> -> values sent: MSB 4, LSB 0..127 -> real NRPN 512..639!!
> ...and so on. 
> 
> This means, that parameters with more than 127 steps will not increase steadily but jump around and certain parameter ranges are unreachable (pretty awful for filter frequency). Also, MSB 127 is never sent, thus I cannot send values 16284...16383 which are needed for negative parameters of my Micron.
> 
> Could anyone please verify this on the BCR2000?
> 
> 
> Last but not least - could anyone please upload the latest files of BC Manager for BCN44 and BCR2000 (http://rapidshare.com/)? It's not available from http://mntn-utils.110mb.com/ anymore :(
> 
> 
> Cheers,
> Andi
>

Attachments

Move to quarantaine

This moves the raw source file on disk only. The archive index is not changed automatically, so you still need to run a manual refresh afterward.