Re: MKS-70 Sysex Script

2010-01-01 by rpcfender

Hi

> The increment commands are correct. The data breakpoints for the 4
> position switches are 0, 32, 64, 96.

$button 42
.showvalue on
.mode incval 32 ;
.default 1
.minmax 0 3
.tx $F0 $41 $36 $07 $24 $20 $01 $0C val $F7 ; MKS 70 Tone A DCO-1 Waveform


This won't give you what you want. You need to increase the minmax value

$button 42
.showvalue on
.mode incval 32
.default 1
.minmax 0 96
.tx $F0 $41 $36 $07 $24 $20 $01 $0C val $F7 ; MKS 70 Tone A DCO-1 Waveform


Note that when you reach 96 the next press returns val to 0
With incval watch out for reversing the minmax values
eg
.minmax 0 3 ;works
.minmax 3 0 ; won't count backwards as you might think

.mode incval -1
.minmax 0 3 ; now this counts backwards


>
> Again, THANK YOU.

Pleasure

Royce

Attachments

Move to quarantaine