--- In bc2000@yahoogroups.com, "tkrumme5000" <tkrumme5000@...> wrote: > Everytime I try to send one of the presets info to my > bcr2000 I use midi-ox and a m-audio uno. It comes up with er22 and > does not accept the sysex dump. I don't know how to successfully send > info to it. Error 22 means something like "invalid message index": each SysEx message in a data dump contains a message index that has to be 1 higher than the one in the previous message. If this is not the case, the BCF2000/BCR2000 rejects the message. At least two potential causes: 1. In theory there could be an error in the source sequence (e.g. syx file), although this isn't very likely. 2. Much more likely: a problem in your MIDI routing, e.g. duplication. For some discussion of duplication, see e.g. "BC Manager Manual" (p. 19), available via http://home.kpn.nl/~f2hmjvandenberg281/bcman.html . I think this issue has also come up before in this forum, so you may try searching the message archive for "Er22" (or "error 22" etc.). Hope this helps, Mark.