hi all, as others in this group, i would like to control my waldorf microwave with my bcr. I can only do that using sysex. I managed to map midi cc to sysex with midiox. I know bc manager can send realtime sysex but only for a few manufacturer. I understand the .ini file for them but don't really know if i can edit one myself for waldorf ? so here is the typical kind of sysex message (i will take the cutoff frequency for exemple) F0h start 3Eh id Waldorf 00h id Microwave I 00h Device ID 0-126 60h RealTimeEdit (start checksum) 00h Instrument N° 0-7 0Xh Parameter MSB 4 Bit (cutoff fonction) 0Xh Parameter LSB 4 Bit (cutoff fonction) YYh raltime controler value (the one i want to change) ZZh Checksum F7h EOX (End) so it gives me in midiox : F0 3E 00 00 60 00 03 00 FB 7F F7 (FB is the realtime value) In fact i would like to know if the bcr can handle this kind of message... thank you
Message
BCR, waldorf microwave and sysex
2010-10-29 by Hervé
Attachments