Bc2000 (for the BCF2000 & BCR2000) group photo

Yahoo Groups archive

Bc2000 (for the BCF2000 & BCR2000)

Index last updated: 2026-04-28 23:16 UTC

Message

Special SysEx Message problem with higher Range than 7 bit

2013-11-27 by <djheikotnt@...>

Hey Guys,

I wanna sending a sysex string to my RS7000 to control the Send1 Delay Effect via Encoder.

"The Range is 1-14860" (Delay Time 0.1ms - 1486.0ms)

F0 43 10 6A 01 02 02 00 val F7

Tried the following code:

# 1 DELAY TIME L - 0.1 ~ 1486.0ms (only an info text)

$encoder 33
.showvalue on
.mode 1dot
.resolution 96 192 384 768
.default 1
.minmax 1 14860
.tx $F0 $43 $10 $6A $01 $02 $02 val0.6 val7.13 $F7

I know this message is not correct...because the Vlue wraps around after the big range needs a higher resolution.
Could it be 14bit?

I uploaded a sreenshot of the RS7000 manual.

please help me :-)


cheers

TNT