Francesco, As Royce stated (way back on August 18 - message 533), Art's .easypar CC 1 16 0 127 relative-3 can be had with .tx $B0 16 ifp 1 ifn $41 This is the.tx code I'm working with for your multiple VPot sysex - but incorporating multiple page/bank -/+ messages at the beginning of the .tx. The ifp/ifn options are wonderful with encoders. Art Hunkins --- In bc2000@yahoogroups.com, "goyya76" <goyya76@...> wrote: > > Hi Royce, > > as you were saying the BCR seems to respond only to CC set up > in .easypar - i could put the relative Vpot message (eg for Vpot1 CC 16 > ch 1, range 0-127, relative-3) but i don't know how to writethe .tx > string inserting a relative value (if it's possible, of course)... > > ciao, > > Francesco >
Message
Re: BCR Sysex from DAW
2007-11-28 by abhunkin
Attachments